CERTIFIED LABORATORIES DIV OF NCH CORP -- 5026 SSC-14 AEROSOL -- 7930-00F025481
=====================  Product Identification  =====================

Product ID:5026 SSC-14 AEROSOL
MSDS Date:12/13/1989
FSC:7930
NIIN:00F025481
=== Responsible Party ===
Company Name:CERTIFIED LABORATORIES DIV OF NCH CORP
Address:2730 CARL RD
Box:152170
City:IRVING
State:TX
ZIP:75061
Country:US
Info Phone Num:214-438-1381
Emergency Phone Num:214-438-1381
Preparer's Name:KEVIN UHL
CAGE:53417
=== Contractor Identification ===
Company Name:CERTIFIED LABS DIV OF NCH CORP
Box:152170
City:IRVING
State:TX
ZIP:75015
Country:US
Phone:214-438-1381972-438-1381
CAGE:53417

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE) (CHLOROTHENE NU),
    AEROTHANE TT, CHLOROTHENE
CAS:71-55-6
RTECS #:KJ2975000
Other REC Limits:450 PPM STEL
OSHA PEL:350 PPM
ACGIH TLV:1910 MG/CUM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Other REC Limits:10000 PPM
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;93

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (RAT): 10,300 MG/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION: HEADACHE, BLURRED VISION,
    NAUSEA & DIZZINESS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: TOXIC. EYES: DAMAGE. INHALATION: TOXIC,
    CENTRAL NERVOUS SYSTEM DEPRESSION.

=======================  First Aid Measures  =======================

First Aid:INHALATION: MOVE TO FRESH AIR. TREAT SYMPTOMS. GIVE OXYGEN IF
    DIFICULT BREATHING. GIVE CPR IF BREATHING STOPS. EYES: FLUSH
    W/WATER 5-6 MINUTES. SKIN: WASH W/SOAP & WATER. INGESTION: DON'T
    INDUCE VOMIT ING. IF IT OCCURS KEEP HEAD BELOW HIPS TO PREVENT
    ASPIRATION OF LIQUID INTO LUNGS. OBTAIN MEDICAL ATTENTION IN ALL
    CASES. PHYSICIAN NOTE: SEE SUPP.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:170F
Extinguishing Media:FOAM, DRY CHEMICAL
Unusual Fire/Explosion Hazard:BURNBACK: >18 INCHES

==================  Accidental Release Measures  ==================

Spill Release Procedures:PREVENT FROM ENTERING SEWER OR WATER SOURCE.
    PICK UP WITH ABSORBENT. CLEAN RESIDUE WITH GOOD DETERGENT.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AT 30-120F. FOLLOW LABEL
    DIRECTIONS. READ ENTIRE LABEL BEFORE USING. KEEP OUT OF REACH OF
    CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:TYPICAL USE OF PRODUCT DOES NOT REQUIRE THE USE
    OF A RESPIRATOR. IF PRODUCT IS MISTED, USE NIOSH APPROVED MASK FOR
    SPRAY MISTS.
Ventilation:GENERAL EXHAUST IS MORE THAN ADEQUATE FOR WORKERS SAFETY.
Supplemental Safety and Health
NOTE TO PHYSICIANS: DEPENDING ON THE AMOUNT INGESTED & RETAINED, AS
    WELL AS THE TOXICITY OF THE PRODUCT, GASTRIC LAVAGE SHOULD BE
    AVOIDED BECAUSE OF PULMONARY ASPIRATION. IF COMATOSE, A CUFFED
    INDOTRA CHEAL TUBE WILL PREVENT ASPIRATION. CONSULT A POISON
    CONTROL CENTER.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:165F
Vapor Pres:43
Vapor Density:4.7
Spec Gravity:0.87
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER ORANGE-SCENTED
Percent Volatiles by Volume:45

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, ACIDS, AND SELECTED AMINES.
Stability Condition to Avoid:N//K
Hazardous Decomposition Products:AT DECOMPOSITON TEMP CAN RELEASE
    CARBON MONOXIDE, HYDROGEN CHLORIDE, AND PHOSGENE IN TRACE AMOUNTS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DO NOT PUNCTURE OR INCINERATE CANS, CHECK WITH
    FEDERAL, STATE AND LOCAL POLLUTION REGULATIONS FOR PROPER DISPOSAL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.