CERTIFIED LABORATORIES DIV OF NCH CORP -- BOLT-OFF AEROSOL, 5075 -- 8010-00N016279
=====================  Product Identification  =====================

Product ID:BOLT-OFF AEROSOL, 5075
MSDS Date:01/11/1990
FSC:8010
NIIN:00N016279
=== Responsible Party ===
Company Name:CERTIFIED LABORATORIES DIV OF NCH CORP
Box:152170
City:IRVING
State:TX
ZIP:75015
Info Phone Num:214-438-1381
Emergency Phone Num:214-438-1381
Preparer's Name:KELLY SEALS/TS CHEMIST
CAGE:53417
=== Contractor Identification ===
Company Name:CERTIFIED LABS DIV OF NCH CORP
Box:152170
City:IRVING
State:TX
ZIP:75015
Country:US
Phone:214-438-1381972-438-1381
CAGE:53417

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE)  (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

Ingred Name:ALIPHATIC PETROLEUM DISTILLATE
CAS:64742-38-7
OSHA PEL:300 PPM (MFR)
ACGIH TLV:400 PPM (MFR)

Ingred Name:ETHYL ACETATE  (SARA III)
CAS:141-78-6
RTECS #:AH5425000
OSHA PEL:400 PPM
ACGIH TLV:400 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;93

Ingred Name:HNDLG/STOR PREC: DISPLACE OXYGEN IN ENCLOSED/CONFINED
    SPACES. GAS/VAPORS MAY ACCUMULATE IN LOW AREAS .
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE INGREDIENT
Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:(ACUTE)INHAL:LRG AMOUNTS CAN LEAD TO
    CNS DEPRESSION,HDCH,DIZZ,NAUSEA & LOSS OF CONSCIOUSNESS.EYE:MAY
    CAUSE IRRIT W/TEARING & TRANSIENT DISCOMFORT. SKIN: UPON
    PRLNGD/RPTD EXP WILL CAUSE LOCAL IRRIT & R EDDENING DUE TO
    DEFATTING WHICH CAN OCCUR. ACCIDENTAL INGEST UNLIKELY DUE TO
    AEROSOL NATURE (SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ: OF PROD. CHRONIC: CNS DEPRESSION,
    KIDNEY DAMAGE, DETMATITIS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:MOVE TO FRESH AIR & TREAT SYMPTOMATICALLY.GIVE O*2 IF
    BRTHG IS DIFFICULT.GIVE ARTF RESP IF BRTHG STOPS.GET MED
    HELP.EYE:FLUSH W/H*2O FOR AT LEAST 15 MIN HOLDING EYELIDS OPEN FOR
    MAX BENEFIT.SEE  PHYS IF IRRIT PERSISTS. SKIN: WASH W/SOAP & H*2O.
    SEE PHYS IF IRRIT PERSISTS. INGEST: DON'T INDUCE VOMIT EVEN IF
    VOMIT OCCURS. IF IT OCCURS, KEEP HEAD BELOW HIPS TO PREVENT ASPIR.
    (SEE SUPP DATA)

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:>200F,>93C
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD POSITIVE PRESSURE SCBA
    AND FULL PROT EQUIPMENT . SPRAY EXPD CNTNRS W/H*2O TO PVNT
    RUPTURING.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODUCTS MAY INCLUDE HCL
    AND PHOSGENE .

==================  Accidental Release Measures  ==================

Spill Release Procedures:MOP/WIPE OR SOAK UP IMMEDIATELY. PROVIDE
    ADEQUATE VENTILATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID BRTHG VAPS.STORE IN COOL,DRY
    PLACE.VAPS ARE >AIR & WILL COLLECT IN LOW AREAS.DON'T ENTER THESE
    AREAS WHERE VAPS ARE SUSPECTED. (SEE OTHER PREC)
Other Precautions:KEEP OUT OF REACH OF CHILDREN.READ ENTIRE LBL BEFORE
    USING PROD.HNDLG/STOR PREC:DO NOT USE WITH POWDERED ZN/AL.NO
    SMOKING IN AREA OF USE.DO NOT USE IN GEN VICINITY OF ARC
    WELDING,OPEN FLAMES/HOT SUFS. HEAT &/OR UV RADIA MAY(SEE SUPP DATA)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPRVD ORGANIC VAP-TYPE RESP REQ IN
    ABSENCE OF PROPER ENVIRONMENTAL CNTRL. FOR EMERGENCIES, A
    NIOSH/MSHA POS-PRESS BRTHG APPAR/FULL-FACE RESP W/APPRVD ORGANIC
    VAP CANISTER IS RECOM. NORMAL  USE OF PROD DOSN'T REQ USE OF ABOVE.
Ventilation:GENERAL EXHAUST IS USUALLY ADEQUATE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Supplemental Safety and Health
FIRST AID PROC:OF LIQ INTO LUNGS.GET MD ATTN IMMED.NOTES TO
    PHYS:DEPENDING ON AMT INGEST & RETAINED AS WELL AS TOXICITY OF
    PROD,GASTRIC LAVAGE SHOULD BE CONSIDERED.IF COMATOSE,A CUFFED
    ENDOTRACHEAL TU BE WILL PVNT ASPIR.HNDLG/STOR PREC:CAUSE FORM OF
    HCL &/OR PHOSGENE.IF BULK/LRG GAS CYLINDERS:MAY (SEE INGRED 5)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:175F,79C
Vapor Pres:73
Vapor Density:3
Spec Gravity:1.320
Evaporation Rate & Reference:5 (BU AC=1)
Solubility in Water:NONE
Appearance and Odor:BROWN, CHLORINATED ODOR.
Percent Volatiles by Volume:88

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
LONG TERM CONTACT CAN PRODUCE CORR ACID. AVOID CONTACT W/ALUMINUM AND
    ITS ALLOYS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HYDROGEN CHLORIDE AND VERY SMALL
    AMOUNTS OF PHOSGENE AND CHLORINE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL FEDERAL, STATE
    AND LOCAL POLLUTION REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.